Customization: | Available |
---|---|
Pattern: | Shear Beam |
Material: | Stainless Steel |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Available models | ||
xxkg | C3/C5/C6/A5M/B10S/B10M | BM8D-xx-xxkg-6B |
xxt | C3/C5/C6/A5M/B10S/B10M | BM8D-xx-xxt-6B |
xxlb | A5M/B10S/B10M | BM8D-xx-xx-6YB |
xxklb | A5M/B10S/B10M | BM8D-xx-xxK-6YB |
50kg-300kg approved by OIML C3. 3.0t-15t approved by OIML C5. 500kg-2.5t approved by OIML C6. 500KG-10t (1klb-20Klb) S1 type approved by NTEP A5S/A5M/B10S/B10M. |
Specification | |||||||
Accuracy class | C3 | C5 | C6 | B10S | A5M | B10M | |
Approvals | OIMLR60 C3 | OIMLR60 C5 | OIMLR60 C6 | ||||
Output sensitivity ( = FS ) | mV/V | 2.0 ± 0.004 | 3.0 ± 0.008 | ||||
Maximum capacity ( Emax ) | t | 0.1/0.15/0.2/0.25/0.3/0.5/1/1.5/2/2.5/3/5/7.5/10 | |||||
klb | 1/1.5/2/2.5KLE/3/4/5/5KSE/7.5/10/15/20 | ||||||
Maximum number of load cell intervals ( nLC ) | 3000 | 5000 | 6000 | IIIL10000 Single |
III5000 Multiple |
IIIL10000 Multiple |
|
Ratio of minimum LC verification interval Y = Emax / vmin | 10000 | 18000 | 20000 | 10000 | 15000 | 10000 | |
Combined error | %FS | ± 0.020 | ± 0.010 | ± 0.009 | ± 0.035 | ± 0.026 | ± 0.050 |
Minimum dead load | %FS | 0 | |||||
Safe overload | %FS | 150 | |||||
Ultimate overload | %FS | 300 | |||||
Zero balance | %FS | ± 1.0 | |||||
Excitation, recommended voltage | V | 5 ~ 12( DC ) | |||||
Excitation maximum | V | 18( DC ) | |||||
Input resistance | Ω | 350 ± 3.5 | |||||
Output resistance | Ω | 350 ± 3.5 | |||||
Insulation resistance | MΩ | ≥ 5000 ( 50VDC ) | |||||
Compensated temperature | ºC | -10 ~+40 | |||||
Operating temperature | ºC | -35 ~ +65 | |||||
Storage temperature | ºC | -40 ~ +70 | |||||
Element material | Stainless steel | ||||||
Recommended torque on fixation | N.m | M12: 75 M20:450 M24:750 | |||||
Ingress protection (according to EN 60529) | IP68 | ||||||
ATEX classification (optional) | II1G Ex ia IIC T4 | II1D Ex iaD 20 T73ºC | II3G Ex nL IIC T4 |