Customization: | Available |
---|---|
Pattern: | Single Point |
Out-Wire: | 4-Wire |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Maximum Capacity | kg | 3/5/8/10/15/20/35/40/50 |
Sensitivity | mV/V | 2.0±0.2 |
Accuracy Class | C3 | |
Maximum numberof load cell intervals |
3000 | |
Temperature effect on zero |
%FS/10ºC | 0.009 |
Temperature effect on span |
%FS/10ºC(-10~40ºC) | 0.0087 |
Combined error | %FS | 0.015 |
Creep/DR (30min) | %FS | 0.0184 |
Input resistance | Ω | 406±6 |
Output resistance | Ω | 350±3 |
Insulation resistance | MΩ | ≥5000(50VDC) |
Zero balance | %FS | 2 |
Nominal temperature range | ºC | -10~+40 |
Operating temperature range | ºC | -35~+65 |
Recommended excitation voltage, |
V | 5~15 |
Safe load limit | %FS | 120 |
Ultimate load limit | %FS | 150 |
Recommend platform size | mm | 400x400 |
Material | Aluminium | |
Protection class | IP66 | |
Sealing | Coated |