Capacity | t | 10/15/20/30/40/50/60/100 | ||||
Accuracy | C2 | C3 | C4 | A5S | A5M | |
Approval | OIML R60 C3 | |||||
Maximum number of verification intervals |
n max | 2000 | 3000 | 4000 | 5000 | 5000 |
Minimum load cell verification interval |
v min | Emax/5000 | Emax/10000 | Emax/14000 | Emax/15000 | Emax/15000 |
Combined error | (%FS) | ≤ 0.030 | ≤± 0.020 | ≤± 0.018 | ≤±0.018 | ≤±0.026 |
Creep | (%FS/30min) | ≤ 0.024 | ≤± 0.016 | ≤± 0.012 | ≤±0.012 | ≤±0.017 |
Temperature effect on sensitivity |
(%FS/10ºC) | ≤ 0.017 | ≤± 0.011 | ≤± 0.009 | ≤±0.009 | ≤±0.013 |
Temperature effect on zero |
(%FS/10 ºC) | ≤ 0.023 | ≤± 0.015 | ≤± 0.010 | ≤±0.010 | ≤±0.014 |
Output sensitivity | (mv/v) | 2.0 ± 0.02 | ||||
Input resistance | ( Ω ) | 700 ± 7 | ||||
Output resistance | ( Ω ) | 703 ± 4 | ||||
Insulation resistance | (M Ω ) | ≥ 5000(50VDC) | ||||
Zero balance | (%FS) | 1.0 | ||||
Temperature, compensated |
( ºC ) | -10~+40 | ||||
Temperature,allowed | ( ºC ) | -35~+65 | ||||
Excitation, Recommended | (V) | 5~12(DC) | ||||
Excitation,Max | (V) | 18(DC) | ||||
Safe overload | (%FS) | 150 | ||||
Ultimate overload | (%FS) | 300 |